I - Mission Critical Classified
Rules and Groups employed by this XCCDF Profile
-
For nonlocal maintenance sessions using SSH, the Juniper SRX Services Gateway must securely configure SSHv2 Message Authentication Code (MAC) algorithms to protect the integrity of maintenance and diagnostic communications.
<VulnDiscussion>To protect the integrity of nonlocal maintenance sessions, SSHv2 with MAC algorithms for integrity checking must be configure...Rule Medium Severity -
SRG-APP-000412-NDM-000331
<GroupDescription></GroupDescription>Group -
For nonlocal maintenance sessions using SNMP, the Juniper SRX Services Gateway must securely configure SNMPv3 with privacy options to protect the confidentiality of maintenance and diagnostic communications for nonlocal maintenance sessions.
<VulnDiscussion>Without confidentiality protection mechanisms, unauthorized individuals may gain access to sensitive information via a remote...Rule High Severity -
SRG-APP-000412-NDM-000331
<GroupDescription></GroupDescription>Group -
For nonlocal maintenance sessions using SSH, the Juniper SRX Services Gateway must securely configured SSHv2 with privacy options to protect the confidentiality of maintenance and diagnostic communications for nonlocal maintenance sessions.
<VulnDiscussion>To protect the confidentiality of nonlocal maintenance sessions when using SSH communications, SSHv2, AES ciphers, and key-ex...Rule Medium Severity