Skip to content

III - Administrative Public

Rules and Groups employed by this XCCDF Profile

  • SRG-APP-000357-NDM-000293

    <GroupDescription></GroupDescription>
    Group
  • The Juniper EX switch must be configured to allocate audit record storage capacity in accordance with organization-defined audit record storage requirements.

    &lt;VulnDiscussion&gt;To ensure network devices have a sufficient storage capacity in which to write the audit logs, they need to be able to alloca...
    Rule Medium Severity
  • SRG-APP-000360-NDM-000295

    <GroupDescription></GroupDescription>
    Group
  • The Juniper EX switch must be configured to generate an immediate real-time alert of all audit failure events requiring real-time alerts.

    &lt;VulnDiscussion&gt;It is critical for the appropriate personnel to be aware if a system is at risk of failing to process audit logs as required....
    Rule Medium Severity
  • SRG-APP-000373-NDM-000298

    <GroupDescription></GroupDescription>
    Group
  • The Juniper EX switch must be configured to synchronize internal information system clocks using redundant authoritative time sources.

    &lt;VulnDiscussion&gt;The loss of connectivity to a particular authoritative time source will result in the loss of time synchronization (free-run ...
    Rule Medium Severity
  • SRG-APP-000374-NDM-000299

    <GroupDescription></GroupDescription>
    Group
  • The Juniper EX switch must be configured to record time stamps for audit records that can be mapped to Coordinated Universal Time (UTC) or Greenwich Mean Time (GMT).

    &lt;VulnDiscussion&gt;If time stamps are not consistently applied and there is no common time reference, it is difficult to perform forensic analys...
    Rule Medium Severity
  • SRG-APP-000378-NDM-000302

    <GroupDescription></GroupDescription>
    Group
  • The Juniper EX switch must be configured to prohibit installation of software without explicit privileged status.

    &lt;VulnDiscussion&gt;Allowing anyone to install software, without explicit privileges, creates the risk that untested or potentially malicious sof...
    Rule Medium Severity