Skip to content

II - Mission Support Public

Rules and Groups employed by this XCCDF Profile

  • SRG-APP-000357-NDM-000293

    <GroupDescription></GroupDescription>
    Group
  • The Juniper EX switch must be configured to allocate audit record storage capacity in accordance with organization-defined audit record storage requirements.

    &lt;VulnDiscussion&gt;To ensure network devices have a sufficient storage capacity in which to write the audit logs, they need to be able to alloca...
    Rule Medium Severity
  • SRG-APP-000360-NDM-000295

    <GroupDescription></GroupDescription>
    Group
  • The Juniper EX switch must be configured to generate an immediate real-time alert of all audit failure events requiring real-time alerts.

    &lt;VulnDiscussion&gt;It is critical for the appropriate personnel to be aware if a system is at risk of failing to process audit logs as required....
    Rule Medium Severity
  • SRG-APP-000373-NDM-000298

    <GroupDescription></GroupDescription>
    Group
  • The Juniper EX switch must be configured to synchronize internal information system clocks using redundant authoritative time sources.

    &lt;VulnDiscussion&gt;The loss of connectivity to a particular authoritative time source will result in the loss of time synchronization (free-run ...
    Rule Medium Severity
  • SRG-APP-000374-NDM-000299

    <GroupDescription></GroupDescription>
    Group
  • The Juniper EX switch must be configured to record time stamps for audit records that can be mapped to Coordinated Universal Time (UTC) or Greenwich Mean Time (GMT).

    &lt;VulnDiscussion&gt;If time stamps are not consistently applied and there is no common time reference, it is difficult to perform forensic analys...
    Rule Medium Severity
  • SRG-APP-000378-NDM-000302

    <GroupDescription></GroupDescription>
    Group
  • The Juniper EX switch must be configured to prohibit installation of software without explicit privileged status.

    &lt;VulnDiscussion&gt;Allowing anyone to install software, without explicit privileges, creates the risk that untested or potentially malicious sof...
    Rule Medium Severity

The content of the drawer really is up to you. It could have form fields, definition lists, text lists, labels, charts, progress bars, etc. Spacing recommendation is 24px margins. You can put tabs in here, and can also make the drawer scrollable.

Capacity
Modules