Skip to content

III - Administrative Classified

Rules and Groups employed by this XCCDF Profile

  • SRG-NET-000343-L2S-000016

    <GroupDescription></GroupDescription>
    Group
  • The Juniper EX switch must be configured to authenticate all network-connected endpoint devices before establishing any connection.

    &lt;VulnDiscussion&gt;Without authenticating devices, unidentified or unknown devices may be introduced, thereby facilitating malicious activity. ...
    Rule Medium Severity
  • SRG-NET-000362-L2S-000021

    <GroupDescription></GroupDescription>
    Group
  • The Juniper EX switch must be configured to enable Root Protection on STP switch ports connecting to access layer switches.

    &lt;VulnDiscussion&gt;Spanning Tree Protocol (STP) does not provide any means for the network administrator to securely enforce the topology of the...
    Rule Low Severity
  • SRG-NET-000362-L2S-000022

    <GroupDescription></GroupDescription>
    Group
  • The Juniper EX switch must be configured to enable BPDU Protection on all user-facing or untrusted access switch ports.

    &lt;VulnDiscussion&gt;If a rogue switch is introduced into the topology and transmits a Bridge Protocol Data Unit (BPDU) with a lower bridge priori...
    Rule Medium Severity
  • SRG-NET-000362-L2S-000023

    <GroupDescription></GroupDescription>
    Group
  • The Juniper EX switch must be configured to enable STP Loop Protection on all non-designated STP switch ports.

    &lt;VulnDiscussion&gt;The Spanning Tree Protocol (STP) Loop Protection feature provides additional protection against STP loops. An STP loop is cre...
    Rule Medium Severity
  • SRG-NET-000362-L2S-000024

    <GroupDescription></GroupDescription>
    Group
  • The Juniper EX switch must be configured not to forward unknown unicast traffic to access interfaces.

    &lt;VulnDiscussion&gt;Access layer switches use the Content Addressable Memory (CAM) table to direct traffic to specific interfaces based on the VL...
    Rule Medium Severity