II - Mission Support Classified
Rules and Groups employed by this XCCDF Profile
-
SRG-NET-000131
<GroupDescription></GroupDescription>Group -
The IDPS must be configured to remove or disable non-essential features, functions, and services of the IDPS application.
<VulnDiscussion>An IDPS can be capable of providing a wide variety of capabilities. Not all of these capabilities are necessary. Unnecessary ...Rule Medium Severity -
SRG-NET-000132
<GroupDescription></GroupDescription>Group -
The IDPS must be configured to prohibit or restrict the use of functions, ports, protocols, and/or services, as defined in the PPSM CAL and vulnerability assessments.
<VulnDiscussion>Some ports, protocols, or services have known exploits or security weaknesses. These ports, protocols, and services must be p...Rule Medium Severity -
SRG-NET-000192
<GroupDescription></GroupDescription>Group -
The IDPS must block outbound traffic containing known and unknown DoS attacks by ensuring that security policies, signatures, rules, and anomaly detection techniques are applied to outbound communications traffic.
<VulnDiscussion>The IDPS must include protection against DoS attacks that originate from inside the enclave which can affect either internal ...Rule Medium Severity -
SRG-NET-000228
<GroupDescription></GroupDescription>Group -
The IDPS must detect, at a minimum, mobile code that is unsigned or exhibiting unusual behavior, has not undergone a risk assessment, or is prohibited for use based on a risk assessment.
<VulnDiscussion>Mobile code is defined as software modules obtained from remote systems, transferred across a network, and then downloaded an...Rule Medium Severity -
SRG-NET-000229
<GroupDescription></GroupDescription>Group -
The IDPS must block any prohibited mobile code at the enclave boundary when it is detected.
<VulnDiscussion>Mobile code is defined as software modules obtained from remote systems, transferred across a network, and then downloaded an...Rule Medium Severity
Node 2