I - Mission Critical Sensitive
Rules and Groups employed by this XCCDF Profile
-
SRG-APP-000840
<GroupDescription></GroupDescription>Group -
The container platform must for password-based authentication, update the list of passwords when organizational passwords are suspected to have been compromised directly or indirectly.
<VulnDiscussion>Password-based authentication applies to passwords regardless of whether they are used in single-factor or multi-factor authe...Rule Medium Severity -
SRG-APP-000845
<GroupDescription></GroupDescription>Group -
The container platform must for password-based authentication, verify when users create or update passwords, that the passwords are not found on the list of commonly-used, expected, or compromised passwords in IA-5 (1) (a).
<VulnDiscussion>Password-based authentication applies to passwords regardless of whether they are used in single-factor or multi-factor authe...Rule Medium Severity -
SRG-APP-000855
<GroupDescription></GroupDescription>Group -
The container platform must for password-based authentication, require immediate selection of a new password upon account recovery.
<VulnDiscussion>Password-based authentication applies to passwords regardless of whether they are used in single-factor or multi-factor authe...Rule Medium Severity -
SRG-APP-000860
<GroupDescription></GroupDescription>Group -
The container platform must for password-based authentication, allow user selection of long passwords and passphrases, including spaces and all printable characters.
<VulnDiscussion>Password-based authentication applies to passwords regardless of whether they are used in single-factor or multi-factor authe...Rule Medium Severity -
SRG-APP-000865
<GroupDescription></GroupDescription>Group -
The container platform must for password-based authentication, employ automated tools to assist the user in selecting strong password authenticators.
<VulnDiscussion>Password-based authentication applies to passwords regardless of whether they are used in single-factor or multi-factor authe...Rule Medium Severity -
SRG-APP-000880
<GroupDescription></GroupDescription>Group -
The container platform must protect nonlocal maintenance sessions by separating the maintenance session from other network sessions with the system by logically separated communications paths.
<VulnDiscussion>Nonlocal maintenance and diagnostic activities are conducted by individuals who communicate through either an external or int...Rule Medium Severity -
SRG-APP-000910
<GroupDescription></GroupDescription>Group -
The container platform must include only approved trust anchors in trust stores or certificate stores managed by the organization.
<VulnDiscussion>Public key infrastructure (PKI) certificates are certificates with visibility external to organizational systems and certific...Rule Medium Severity -
SRG-APP-000915
<GroupDescription></GroupDescription>Group -
The container platform must provide protected storage for cryptographic keys with organization-defined safeguards and/or hardware protected key store.
<VulnDiscussion>A Trusted Platform Module (TPM) is an example of a hardware-protected data store that can be used to protect cryptographic ke...Rule Medium Severity -
SRG-APP-000920
<GroupDescription></GroupDescription>Group -
The container platform must synchronize system clocks within and between systems or system components.
<VulnDiscussion>Time synchronization of system clocks is essential for the correct execution of many system services, including identificatio...Rule Medium Severity
Node 2