Skip to content

I - Mission Critical Sensitive

Rules and Groups employed by this XCCDF Profile

  • SRG-APP-000164-NDM-000252

    <GroupDescription></GroupDescription>
    Group
  • The CA API Gateway must enforce a minimum 15-character password length.

    &lt;VulnDiscussion&gt;Password complexity, or strength, is a measure of the effectiveness of a password in resisting attempts at guessing and brute...
    Rule Medium Severity
  • SRG-APP-000170-NDM-000329

    <GroupDescription></GroupDescription>
    Group
  • If multifactor authentication is not supported and passwords must be used, the CA API Gateway must require that when a password is changed, the characters are changed in at least 8 of the positions within the password.

    &lt;VulnDiscussion&gt;If the application allows the user to consecutively reuse extensive portions of passwords, this increases the chances of pass...
    Rule Medium Severity
  • SRG-APP-000234-NDM-000272

    <GroupDescription></GroupDescription>
    Group
  • The CA API Gateway must automatically remove or disable emergency accounts, except the emergency administration account, after 72 hours.

    &lt;VulnDiscussion&gt;Emergency accounts are administrator accounts which are established in response to crisis situations where the need for rapid...
    Rule Medium Severity
  • SRG-APP-000268-NDM-000274

    <GroupDescription></GroupDescription>
    Group
  • The CA API Gateway must activate a system alert message, send an alarm, and/or automatically shut down when a component failure is detected.

    &lt;VulnDiscussion&gt;Predictable failure prevention requires organizational planning to address device failure issues. If components key to mainta...
    Rule Medium Severity
  • SRG-APP-000320-NDM-000284

    <GroupDescription></GroupDescription>
    Group
  • The CA API Gateway must notify System Administrators (SAs) and Information System Security Officers (ISSMs) when accounts are created, or enabled when previously disabled.

    &lt;VulnDiscussion&gt;Once an attacker establishes initial access to a system, the attacker often attempts to create a persistent method of reestab...
    Rule Medium Severity

The content of the drawer really is up to you. It could have form fields, definition lists, text lists, labels, charts, progress bars, etc. Spacing recommendation is 24px margins. You can put tabs in here, and can also make the drawer scrollable.

Capacity
Modules