I - Mission Critical Classified

Rules and Groups employed by this XCCDF Profile

  • SRG-APP-000142

    <GroupDescription></GroupDescription>
    Group
  • AAA Services must be configured to use secure protocols when connecting to directory services.

    &lt;VulnDiscussion&gt;Authenticity protection provides protection against man-in-the-middle attacks/session hijacking and the insertion of false in...
    Rule High Severity
  • SRG-APP-000142

    <GroupDescription></GroupDescription>
    Group
  • AAA Services must be configured to use protocols that encrypt credentials when authenticating clients, as defined in the PPSM CAL and vulnerability assessments.

    &lt;VulnDiscussion&gt;Authentication protection of the client credentials (specifically the password or shared secret) prevents unauthorized access...
    Rule High Severity
  • SRG-APP-000142

    <GroupDescription></GroupDescription>
    Group
  • AAA Services must be configured to prohibit or restrict the use of organization-defined functions, ports, protocols, and/or services, as defined in the PPSM CAL and vulnerability assessments.

    &lt;VulnDiscussion&gt;In order to prevent unauthorized connection of devices, unauthorized transfer of information, or unauthorized tunneling (i.e....
    Rule Medium Severity
  • SRG-APP-000148

    <GroupDescription></GroupDescription>
    Group
  • AAA Services must be configured to uniquely identify and authenticate organizational users.

    &lt;VulnDiscussion&gt;To assure accountability and prevent unauthenticated access, organizational users must be identified and authenticated to pre...
    Rule High Severity
  • SRG-APP-000149

    <GroupDescription></GroupDescription>
    Group
  • AAA Services must be configured to require multifactor authentication using Personal Identity Verification (PIV) credentials for authenticating privileged user accounts.

    &lt;VulnDiscussion&gt;Without the use of multifactor authentication, the ease of access to privileged functions is greatly increased. Multifactor...
    Rule Medium Severity