Skip to content

I - Mission Critical Classified

Rules and Groups employed by this XCCDF Profile

  • SRG-APP-000096

    <GroupDescription></GroupDescription>
    Group
  • AAA Services configuration audit records must identify when (date and time) the events occurred.

    &lt;VulnDiscussion&gt;Without establishing when events occurred, it is impossible to establish, correlate, and investigate the events relating to a...
    Rule Medium Severity
  • SRG-APP-000097

    <GroupDescription></GroupDescription>
    Group
  • AAA Services configuration audit records must identify where the events occurred.

    &lt;VulnDiscussion&gt;Without establishing where events occurred, it is impossible to establish, correlate, and investigate the events relating to ...
    Rule Medium Severity
  • SRG-APP-000098

    <GroupDescription></GroupDescription>
    Group
  • AAA Services configuration audit records must identify the source of the events.

    &lt;VulnDiscussion&gt;Without establishing the source of the event, it is impossible to establish, correlate, and investigate the events leading up...
    Rule Medium Severity
  • SRG-APP-000099

    <GroupDescription></GroupDescription>
    Group
  • AAA Services configuration audit records must identify the outcome of the events.

    &lt;VulnDiscussion&gt;Without information about the outcome of events, security personnel cannot make an accurate assessment as to whether an attac...
    Rule Medium Severity
  • SRG-APP-000100

    <GroupDescription></GroupDescription>
    Group
  • AAA Services configuration audit records must identify any individual user or process associated with the event.

    &lt;VulnDiscussion&gt;Without information that establishes the identity of the subjects (i.e., users or processes acting on behalf of users) associ...
    Rule Medium Severity
  • SRG-APP-000108

    <GroupDescription></GroupDescription>
    Group
  • AAA Services must be configured to alert the SA and ISSO when any audit processing failure occurs.

    &lt;VulnDiscussion&gt;It is critical for the appropriate personnel to be aware if a system is at risk of failing to process audit logs as required....
    Rule Medium Severity
  • SRG-APP-000109

    <GroupDescription></GroupDescription>
    Group
  • AAA Services must be configured to generate audit records overwriting the oldest audit records in a first-in-first-out manner.

    &lt;VulnDiscussion&gt;It is critical that when AAA Services are at risk of failing to process audit logs as required, they take action to mitigate ...
    Rule Medium Severity
  • SRG-APP-000109

    <GroupDescription></GroupDescription>
    Group
  • AAA Services must be configured to queue audit records locally until communication is restored when any audit processing failure occurs.

    &lt;VulnDiscussion&gt;It is critical that when AAA Services are at risk of failing to process audit logs as required, it take action to mitigate th...
    Rule Medium Severity
  • SRG-APP-000116

    <GroupDescription></GroupDescription>
    Group
  • AAA Services must be configured to use internal system clocks to generate time stamps for audit records.

    &lt;VulnDiscussion&gt;Without an internal clock used as the reference for the time stored on each event to provide a trusted common reference for t...
    Rule Medium Severity
  • SRG-APP-000141

    <GroupDescription></GroupDescription>
    Group
  • AAA Services must be configured to disable non-essential modules.

    &lt;VulnDiscussion&gt;It is detrimental for applications to provide, or install by default, functionality exceeding requirements or mission objecti...
    Rule Medium Severity

The content of the drawer really is up to you. It could have form fields, definition lists, text lists, labels, charts, progress bars, etc. Spacing recommendation is 24px margins. You can put tabs in here, and can also make the drawer scrollable.

Capacity
Modules