Skip to content

II - Mission Support Public

Rules and Groups employed by this XCCDF Profile

  • SRG-APP-000373-NDM-000298

    <GroupDescription></GroupDescription>
    Group
  • The Arista network device must be configured to synchronize internal system clocks using redundant authenticated time sources.

    &lt;VulnDiscussion&gt;The loss of connectivity to a particular authoritative time source will result in the loss of time synchronization (free-run ...
    Rule Medium Severity
  • SRG-APP-000395-NDM-000310

    <GroupDescription></GroupDescription>
    Group
  • The Arista network device must be configured to authenticate SNMP messages using a FIPS-validated Keyed-Hash Message Authentication Code (HMAC).

    &lt;VulnDiscussion&gt;Without authenticating devices, unidentified or unknown devices may be introduced, thereby facilitating malicious activity. B...
    Rule Medium Severity
  • SRG-APP-000411-NDM-000330

    <GroupDescription></GroupDescription>
    Group
  • The Arista network devices must use FIPS-validated Keyed-Hash Message Authentication Code (HMAC) to protect the integrity of remote maintenance sessions.

    &lt;VulnDiscussion&gt;Unapproved mechanisms used for authentication to the cryptographic module are not verified and therefore cannot be relied upo...
    Rule High Severity
  • SRG-APP-000412-NDM-000331

    <GroupDescription></GroupDescription>
    Group
  • The Arista network device must be configured to implement cryptographic mechanisms using a FIPS 140-2 approved algorithm to protect the confidentiality of remote maintenance sessions.

    &lt;VulnDiscussion&gt;This requires the use of secure protocols instead of their unsecured counterparts, such as SSH instead of telnet, SCP instead...
    Rule High Severity
  • SRG-APP-000095-NDM-000225

    <GroupDescription></GroupDescription>
    Group
  • The Arista network device must be configured to capture all DOD auditable events.

    &lt;VulnDiscussion&gt;Auditing and logging are key components of any security architecture. Logging the actions of specific events provides a means...
    Rule Medium Severity