  • SRG-APP-000068

    <GroupDescription></GroupDescription>
    Group
  • The publicly accessible Tanium application must display the Standard Mandatory DOD Notice and Consent Banner before granting access to the application.

    &lt;VulnDiscussion&gt;Display of a standardized and approved use notification before granting access to the publicly accessible application ensures...
    Rule Medium Severity
  • SRG-APP-000069

    <GroupDescription></GroupDescription>
    Group
  • The publicly accessible Tanium application must retain the Standard Mandatory DOD Notice and Consent Banner on the screen until users acknowledge the usage conditions and take explicit actions to log on for further access.

    &lt;VulnDiscussion&gt;Display of a standardized and approved use notification before granting access to the publicly accessible application ensures...
    Rule Medium Severity
  • SRG-APP-000080

    <GroupDescription></GroupDescription>
    Group
  • Multi-factor authentication must be enabled and enforced on the Tanium Server for all access and all accounts.

    &lt;VulnDiscussion&gt;To ensure accountability and prevent unauthenticated access, organizational users must be identified and authenticated to pre...
    Rule Medium Severity
  • SRG-APP-000108

    <GroupDescription></GroupDescription>
    Group
  • The Tanium application must alert the ISSO and SA (at a minimum) in the event of an audit processing failure.

    &lt;VulnDiscussion&gt;It is critical for the appropriate personnel to be aware if a system is at risk of failing to process audit logs as required....
    Rule Medium Severity
  • SRG-APP-000111

    <GroupDescription></GroupDescription>
    Group
  • The Tanium application must be configured to send audit records from multiple components within the system to a central location for review and analysis of audit records.

    &lt;VulnDiscussion&gt;Successful incident response and auditing relies on timely, accurate system information and analysis to allow the organizatio...