Skip to content

II - Mission Support Public

Rules and Groups employed by this XCCDF Profile

  • SRG-APP-000345-NDM-000290

    Group
  • Riverbed Optimization System (RiOS) must automatically lock the account until the locked account is released by an administrator when three unsuccessful login attempts in 15 minutes are exceeded.

    By limiting the number of failed login attempts, the risk of unauthorized system access via user password guessing, otherwise known as brute-forcing, is reduced. Limits are imposed by locking the a...
    Rule Medium Severity
  • SRG-APP-000068-NDM-000215

    Group
  • Riverbed Optimization System (RiOS) must display the Standard Mandatory DoD Notice and Consent Banner before granting access to the device.

    Display of the DoD-approved use notification before granting access to the network device ensures privacy and security notification verbiage used is consistent with applicable federal laws, Executi...
    Rule Medium Severity
  • SRG-APP-000001-NDM-000200

    Group
  • Riverbed Optimization System (RiOS) must limit the number of concurrent sessions to one (1) for each administrator account and/or administrator account type.

    Device management includes the ability to control the number of administrators and management sessions that manage a device. Limiting the number of allowed administrators and sessions per administr...
    Rule Medium Severity
  • SRG-APP-000295-NDM-000279

    Group
  • Riverbed Optimization System (RiOS) must automatically terminate a network administrator session after organization-defined conditions or trigger events requiring session disconnect.

    Automatic session termination addresses the termination of administrator-initiated logical sessions in contrast to the termination of network connections that are associated with communications ses...
    Rule Medium Severity
  • SRG-APP-000101-NDM-000231

    Group
  • Riverbed Optimization System (RiOS) must generate audit records containing the full-text recording of privileged commands.

    Reconstruction of harmful events or forensic analysis is not possible if audit records do not contain enough information. Organizations consider limiting the additional audit information to only ...
    Rule Medium Severity

The content of the drawer really is up to you. It could have form fields, definition lists, text lists, labels, charts, progress bars, etc. Spacing recommendation is 24px margins. You can put tabs in here, and can also make the drawer scrollable.

Capacity