I - Mission Critical Classified

Rules and Groups employed by this XCCDF Profile

  • SRG-NET-000131

    <GroupDescription></GroupDescription>
    Group
  • The router must be configured to have all non-essential capabilities disabled.

    &lt;VulnDiscussion&gt;A compromised router introduces risk to the entire network infrastructure, as well as data resources that are accessible via ...
    Rule Low Severity
  • SRG-NET-000168

    <GroupDescription></GroupDescription>
    Group
  • The router must be configured to use encryption for routing protocol authentication.

    &lt;VulnDiscussion&gt;A rogue router could send a fictitious routing update to convince a site's perimeter router to send traffic to an incorrect o...
    Rule Medium Severity
  • SRG-NET-000168

    <GroupDescription></GroupDescription>
    Group
  • The router must be configured to authenticate all routing protocol messages using NIST-validated FIPS 198-1 message authentication code algorithm.

    &lt;VulnDiscussion&gt;A rogue router could send a fictitious routing update to convince a site's perimeter router to send traffic to an incorrect o...
    Rule Medium Severity
  • SRG-NET-000192

    <GroupDescription></GroupDescription>
    Group
  • The PE router must be configured to limit the number of MAC addresses it can learn for each Virtual Private LAN Services (VPLS) bridge domain.

    &lt;VulnDiscussion&gt;VPLS defines an architecture that delivers Ethernet multipoint services over an MPLS network. Customer Layer 2 frames are for...
    Rule Medium Severity
  • SRG-NET-000193

    <GroupDescription></GroupDescription>
    Group
  • The MPLS router with RSVP-TE enabled must be configured with message pacing or refresh reduction to adjust maximum number of RSVP messages to an output queue based on the link speed and input queue size of adjacent core routers.

    &lt;VulnDiscussion&gt;RSVP-TE can be used to perform constraint-based routing when building LSP tunnels within the network core that will support Q...
    Rule Low Severity