Skip to content

I - Mission Critical Classified

Rules and Groups employed by this XCCDF Profile

  • SRG-APP-000340-WSR-000029

    <GroupDescription></GroupDescription>
    Group
  • Non-privileged accounts on the hosting system must only access OHS security-relevant information and functions through a distinct administrative account.

    &lt;VulnDiscussion&gt;By separating web server security functions from non-privileged users, roles can be developed that can then be used to admini...
    Rule Medium Severity
  • SRG-APP-000089-WSR-000047

    <GroupDescription></GroupDescription>
    Group
  • OHS must have the client requests logging module loaded to generate log records for system startup and shutdown, system access, and system authentication logging.

    &lt;VulnDiscussion&gt;Log records can be generated from various components within the web server (e.g., httpd, plug-ins to external backends, etc.)...
    Rule Medium Severity
  • SRG-APP-000089-WSR-000047

    <GroupDescription></GroupDescription>
    Group
  • OHS must have OraLogMode set to Oracle Diagnostic Logging text mode to generate log records for system startup and shutdown, system access, and system authentication logging.

    &lt;VulnDiscussion&gt;Log records can be generated from various components within the web server (e.g., httpd, plug-ins to external backends, etc.)...
    Rule Medium Severity
  • SRG-APP-000089-WSR-000047

    <GroupDescription></GroupDescription>
    Group
  • OHS must have a log directory location defined to generate log records for system startup and shutdown, system access, and system authentication logging.

    &lt;VulnDiscussion&gt;Log records can be generated from various components within the web server (e.g., httpd, plug-ins to external backends, etc.)...
    Rule Medium Severity
  • SRG-APP-000089-WSR-000047

    <GroupDescription></GroupDescription>
    Group
  • OHS must have a log level severity defined to generate adequate log records for system startup and shutdown, system access, and system authentication events.

    &lt;VulnDiscussion&gt;Log records can be generated from various components within the web server (e.g., httpd, plug-ins to external backends, etc.)...
    Rule Medium Severity
  • SRG-APP-000089-WSR-000047

    <GroupDescription></GroupDescription>
    Group
  • OHS must have the log rotation parameter set to allow for the generation log records for system startup and shutdown, system access, and system authentication events.

    &lt;VulnDiscussion&gt;Log records can be generated from various components within the web server (e.g., httpd, plug-ins to external backends, etc.)...
    Rule Medium Severity
  • SRG-APP-000089-WSR-000047

    <GroupDescription></GroupDescription>
    Group
  • OHS must have a log format defined to generate adequate logs by system startup and shutdown, system access, and system authentication events.

    &lt;VulnDiscussion&gt;Log records can be generated from various components within the web server (e.g., httpd, plug-ins to external backends, etc.)...
    Rule Medium Severity
  • SRG-APP-000089-WSR-000047

    <GroupDescription></GroupDescription>
    Group
  • OHS must have a SSL log format defined to generate adequate logs by system startup and shutdown, system access, and system authentication events.

    &lt;VulnDiscussion&gt;Log records can be generated from various components within the web server (e.g., httpd, plug-ins to external backends, etc.)...
    Rule Medium Severity
  • SRG-APP-000089-WSR-000047

    <GroupDescription></GroupDescription>
    Group
  • OHS must have a log file defined for each site/virtual host to capture logs generated by system startup and shutdown, system access, and system authentication events.

    &lt;VulnDiscussion&gt;Log records can be generated from various components within the web server (e.g., httpd, plug-ins to external backends, etc.)...
    Rule Medium Severity
  • SRG-APP-000095-WSR-000056

    <GroupDescription></GroupDescription>
    Group
  • OHS must have a log level severity defined to produce sufficient log records to establish what type of events occurred.

    &lt;VulnDiscussion&gt;Web server logging capability is critical for accurate forensic analysis. Without sufficient and accurate information, a corr...
    Rule Medium Severity