I - Mission Critical Classified

Rules and Groups employed by this XCCDF Profile

  • SRG-OS-000033-GPOS-00014

    Group
  • Nutanix AOS must implement DoD-approved encryption to protect the confidentiality of remote access sessions.

    Without confidentiality protection mechanisms, unauthorized individuals may gain access to sensitive information via a remote access session. Remote access is access to DoD nonpublic information s...
    Rule High Severity
  • SRG-OS-000002-GPOS-00002

    Group
  • Nutanix AOS must automatically remove or disable temporary user accounts after 72 hours.

    If temporary user accounts remain active when no longer needed or for an excessive period, these accounts may be used to gain unauthorized access. To mitigate this risk, automated termination of al...
    Rule Low Severity
  • SRG-OS-000004-GPOS-00004

    Group
  • Nutanix AOS must audit all account actions.

    Once an attacker establishes access to a system, the attacker often attempts to create a persistent method of reestablishing access. One way to accomplish this is for the attacker to create an acco...
    Rule Medium Severity
  • SRG-OS-000080-GPOS-00048

    Group
  • Nutanix AOS must be configured with an encrypted boot password for root.

    To mitigate the risk of unauthorized access to sensitive information by entities that have been issued certificates by DoD-approved PKIs, all DoD systems (e.g., web servers and web portals) must be...
    Rule Low Severity
  • SRG-OS-000312-GPOS-00122

    Group
  • Nutanix AOS must enforce discretionary access control on symlinks and hardlinks.

    Discretionary Access Control (DAC) is based on the notion that individual users are "owners" of objects and therefore have discretion over who should be authorized to access the object and in which...
    Rule Medium Severity