Skip to content

III - Administrative Classified

Rules and Groups employed by this XCCDF Profile

  • SRG-APP-000231-DNS-000033

    <GroupDescription></GroupDescription>
    Group
  • The Windows 2012 DNS Server must protect secret/private cryptographic keys while at rest.

    &lt;VulnDiscussion&gt;Information at rest refers to the state of information when it is located on a secondary storage device within an organizatio...
    Rule Medium Severity
  • SRG-APP-000428-DNS-000061

    <GroupDescription></GroupDescription>
    Group
  • The Windows 2012 DNS Server must not contain zone records that have not been validated in over a year.

    &lt;VulnDiscussion&gt;If zone information has not been validated in over a year, then there is no assurance that it is still valid. If invalid rec...
    Rule Medium Severity
  • SRG-APP-000246-DNS-000035

    <GroupDescription></GroupDescription>
    Group
  • The Windows 2012 DNS Server must restrict individuals from using it for launching Denial of Service (DoS) attacks against other information systems.

    &lt;VulnDiscussion&gt;Applications and application developers must take the steps needed to ensure users cannot use an authorized application to la...
    Rule Medium Severity
  • SRG-APP-000247-DNS-000036

    <GroupDescription></GroupDescription>
    Group
  • The Windows 2012 DNS Server must use DNS Notify to prevent denial of service through increase in workload.

    &lt;VulnDiscussion&gt;In the case of application DoS attacks, care must be taken when designing the application to ensure the application makes the...
    Rule Medium Severity
  • SRG-APP-000439-DNS-000063

    <GroupDescription></GroupDescription>
    Group
  • The Windows 2012 DNS Server must protect the integrity of transmitted information.

    &lt;VulnDiscussion&gt;Without protection of the transmitted information, confidentiality and integrity may be compromised since unprotected communi...
    Rule Medium Severity