Skip to content

III - Administrative Public

Rules and Groups employed by this XCCDF Profile

  • SRG-APP-000033-NDM-000212

    Group
  • The Microsoft SCOM administration console must only be installed on Management Servers and hardened Privileged Access Workstations.

    The Microsoft SCOM management servers are considered high value IT resources where compromise would cause a significant impact to the organization. The Operations Manager console contains APIs that...
    Rule Low Severity
  • SRG-APP-000033-NDM-000212

    Group
  • The Microsoft SCOM Service Accounts and Run As accounts must not be granted enterprise or domain level administrative privileges.

    The Microsoft SCOM privileged Run As accounts are used to execute work flow tasks on target endpoints. A SCOM Run As account must only have the level of privileges required to perform the defined S...
    Rule High Severity
  • SRG-APP-000033-NDM-000212

    Group
  • SCOM SQL Management must be configured to use least privileges.

    Microsoft SCOM's SQL management requires a Run as solution because the local system account will not have the required permissions to monitor SQL. If the Run As account is created with elevated da...
    Rule High Severity
  • SRG-APP-000516-NDM-000340

    Group
  • The Microsoft SCOM server must back up audit records at least every seven days onto a different system or system component than the system or component being audited.

    Protection of log data includes assuring log data is not accidentally lost or deleted. Regularly backing up audit records to a different system or onto separate media than the system being audited ...
    Rule Medium Severity
  • SRG-APP-000516-NDM-000351

    Group
  • The Microsoft SCOM server must be running Windows operating system that supports modern security features such as virtualization based security.

    Network devices running older but supported operating systems lack modern security features that mitigate attack surfaces. Attackers face a higher level of complexity to overcome during a compromis...
    Rule High Severity