I - Mission Critical Public
Rules and Groups employed by this XCCDF Profile
-
SRG-APP-000389-NDM-000306
Group -
The DataPower Gateway must require users to re-authenticate when privilege escalation or role changes occur.
Without re-authentication, users may access resources or perform tasks for which they do not have authorization. When devices provide the capability to change security roles, it is critical the us...Rule Medium Severity -
SRG-APP-000395-NDM-000310
Group -
The DataPower Gateway must use SNMPv3.
Without authenticating devices, unidentified or unknown devices may be introduced, thereby facilitating malicious activity. Bidirectional authentication provides stronger safeguards to validate the...Rule High Severity -
SRG-APP-000400-NDM-000313
Group -
The DataPower Gateway must prohibit the use of cached authenticators after an organization-defined time period.
Some authentication implementations can be configured to use cached authenticators. If cached authentication information is out-of-date, the validity of the authentication information may be quest...Rule Medium Severity -
SRG-APP-000411-NDM-000330
Group -
The IBM DataPower Gateway must only allow the use of protocols that implement cryptographic mechanisms to protect the integrity and confidentiality of management communications.
This requires the use of secure protocols instead of their unsecured counterparts, such as SSH instead of telnet, SCP instead of FTP, and HTTPS instead of HTTP. If unsecured protocols (lacking cryp...Rule Medium Severity -
SRG-APP-000515-NDM-000325
Group -
The DataPower Gateway must off-load audit records onto a different system or media than the system being audited.
Information stored in one location is vulnerable to accidental or incidental deletion or alteration. Off-loading is a common process in information systems with limited audit storage capacity.Rule Medium Severity -
SRG-APP-000516-NDM-000333
Group -
The DataPower Gateway must use automated mechanisms to alert security personnel to threats identified by authoritative sources (e.g., CTOs) and in accordance with CJCSM 6510.01B.
By immediately displaying an alarm message, potential security violations can be identified more quickly even when administrators are not logged into the network device. An example of a mechanism t...Rule Medium Severity -
SRG-APP-000516-NDM-000334
Group -
The DataPower Gateway must generate audit log events for a locally developed list of auditable events.
Auditing and logging are key components of any security architecture. Logging the actions of specific events provides a means to investigate an attack; to recognize resource utilization or capacity...Rule Medium Severity -
SRG-APP-000516-NDM-000336
Group -
The DataPower Gateway must employ automated mechanisms to centrally manage authentication settings.
The use of authentication servers or other centralized management servers for providing centralized authentication services is required for network device management. Maintaining local administrato...Rule Medium Severity -
SRG-APP-000516-NDM-000337
Group -
The DataPower Gateway must employ automated mechanisms to centrally apply authentication settings.
The use of authentication servers or other centralized management servers for providing centralized authentication services is required for network device management. Maintaining local administrato...Rule Medium Severity -
SRG-APP-000516-NDM-000338
Group -
The DataPower Gateway must employ automated mechanisms to centrally verify authentication settings.
The use of authentication servers or other centralized management servers for providing centralized authentication services is required for network device management. Maintaining local administrato...Rule Medium Severity