I - Mission Critical Classified
Rules and Groups employed by this XCCDF Profile
-
SRG-OS-000123-GPOS-00064
<GroupDescription></GroupDescription>Group -
The storage system must be configured to have only 1 emergency account which can be accessed without LDAP, and which has full administrator capabilities.
<VulnDiscussion>While LDAP allows the storage system to support stronger authentication and provides additional auditing, it also places a de...Rule High Severity -
SRG-OS-000001-GPOS-00001
<GroupDescription></GroupDescription>Group -
The storage system must only be operated in conjunction with an LDAP server in a trusted environment if an Active Directory server is not available.
<VulnDiscussion>Where strong account and password management capabilities are required, the 3PAR system is heavily dependent on its ability t...Rule High Severity -
SRG-OS-000125-GPOS-00065
<GroupDescription></GroupDescription>Group -
User credentials which would allow remote access to the system by the Service Processor must be removed from the storage system.
<VulnDiscussion>Failure to remove the default user accounts associated with remote access from the Service Processor increases the risk of un...Rule High Severity -
SRG-OS-000001-GPOS-00001
<GroupDescription></GroupDescription>Group -
The storage system must only be operated in conjunction with an Active Directory server in a trusted environment if an LDAP server is not available.
<VulnDiscussion>Where strong account and password management capabilities are required, the 3PAR system is heavily dependent on its ability t...Rule High Severity -
SRG-OS-000078-GPOS-00046
<GroupDescription></GroupDescription>Group -
The storage system must require passwords contain a minimum of 15 characters, after an administrator has set the minimum password length to that value.
<VulnDiscussion>The shorter the password, the lower the number of possible combinations that need to be tested before the password is comprom...Rule Medium Severity