  • SRG-OS-000077-GPOS-00045

    Group
  • The PASSWORD History Count value must be set to 10 or greater.

    History Count specifies the number of previous passwords saved for each USERID and compares it with an intended new password. If there is a match with one of the previous passwords, or with the cur...
    Rule Medium Severity
  • SRG-OS-000076-GPOS-00044

    Group
  • The PASSWORD expiration day(s) value must be set to equal or less then 60 days.

    Expiration Day(s) specifies the maximum number of days that each user's password is valid. When a user logs on to the Hardware Management Console it compares the system password interval value spec...
    Rule Medium Severity
  • SRG-OS-000021-GPOS-00005

    Group
  • Maximum failed password attempts before disable delay must be set to 3 or less.

    The Maximum failed attempts before disable delay is not set to 3. This specifies the number of consecutive incorrect password attempts the Hardware Management Console allows as 3 times, before sett...
    Rule Medium Severity
  • SRG-OS-000329-GPOS-00128

    Group
  • A maximum of 60-minute delay must be specified for the password retry after 3 failed attempts to enter your password

    The Maximum failed attempts before disable delay is not set to 3. This specifies the number of consecutive incorrect password attempts the Hardware Management Console allows as 3 times, before sett...
    Rule Low Severity
  • SRG-OS-000069-GPOS-00037

    Group
  • The password values must be set to meet the requirements in accordance with DODI 8500.2 for DoD information systems processing sensitive information and above, and CJCSI 6510.01E (INFORMATION ASSURANCE [IA] AND COMPUTER NETWORK DEFENSE [CND]).

    In accordance with DODI 8500.2 for DOD information systems processing sensitive information and above and CJCSI 6510.01E (INFORMATION ASSURANCE [IA] AND COMPUTER NETWORK DEFENSE [CND]). The followi...
    Rule Medium Severity