Skip to content

III - Administrative Public

Rules and Groups employed by this XCCDF Profile

  • SRG-APP-000096-DB-000040

    Group
  • PostgreSQL must produce audit records containing time stamps to establish when the events occurred.

    Information system auditing capability is critical for accurate forensic analysis. Without establishing when events occurred, it is impossible to establish, correlate, and investigate the events re...
    Rule Medium Severity
  • SRG-APP-000123-DB-000204

    Group
  • PostgreSQL must protect its audit features from unauthorized removal.

    Protecting audit data also includes identifying and protecting the tools used to view and manipulate log data. Therefore, protecting audit tools is necessary to prevent unauthorized operation on au...
    Rule Medium Severity
  • SRG-APP-000515-DB-000318

    Group
  • PostgreSQL must off-load audit data to a separate log management facility; this must be continuous and in near real time for systems with a network connection to the storage facility and weekly or more often for stand-alone systems.

    Information stored in one location is vulnerable to accidental or incidental deletion or alteration. Off-loading is a common process in information systems with limited audit storage capacity. P...
    Rule Medium Severity
  • SRG-APP-000224-DB-000384

    Group
  • PostgreSQL must maintain the authenticity of communications sessions by guarding against man-in-the-middle attacks that guess at Session ID values.

    One class of man-in-the-middle, or session hijacking, attack involves the adversary guessing at valid session identifiers based on patterns in identifiers already known. The preferred technique fo...
    Rule Medium Severity
  • SRG-APP-000148-DB-000103

    Group
  • PostgreSQL must uniquely identify and authenticate organizational users (or processes acting on behalf of organizational users).

    To ensure accountability and prevent unauthenticated access, organizational users must be identified and authenticated to prevent potential misuse and compromise of the system. Organizational use...
    Rule Medium Severity