Skip to content

I - Mission Critical Public

Rules and Groups employed by this XCCDF Profile

  • PP-MDM-991000

    Group
  • The Samsung SDS EMM must enforce the limit of three consecutive invalid logon attempts by a user.

    By limiting the number of failed login attempts, the risk of unauthorized system access via user password guessing, otherwise known as brute forcing, is reduced. Limits are imposed by locking the a...
    Rule Medium Severity
  • PP-MDM-991000

    Group
  • The Samsung SDS EMM must use multifactor authentication for local access to privileged accounts.

    To ensure accountability and prevent unauthenticated access, privileged users must use multifactor authentication to prevent potential misuse and compromise of the system. Multifactor authenticat...
    Rule Medium Severity
  • PP-MDM-414002

    Group
  • The Samsung SDS EMM must be configured to leverage the MDM platform administrator accounts and groups for Samsung SDS EMM user identification and CAC authentication.

    A comprehensive account management process that includes automation helps to ensure the accounts designated as requiring attention are consistently and promptly addressed. If an attacker compromise...
    Rule High Severity
  • PP-MDM-414003

    Group
  • Authentication of MDM platform accounts must be configured so they are implemented via an enterprise directory service.

    A comprehensive account management process that includes automation helps to ensure the accounts designated as requiring attention are consistently and promptly addressed. If an attacker compromise...
    Rule High Severity
  • PP-MDM-991000

    Group
  • The Samsung SDS EMM local accounts password must be configured with length of 15 characters.

    The shorter the password, the lower the number of possible combinations that need to be tested before the password is compromised. Password complexity, or strength, is a measure of the effective...
    Rule Medium Severity