II - Mission Support Sensitive
Rules and Groups employed by this XCCDF Profile
-
SRG-APP-000372-NDM-000297
Group -
The Arista Multilayer Switch must synchronize internal information system clocks to the authoritative time source when the time difference is greater than the organization-defined time period.
Inaccurate time stamps make it more difficult to correlate events and can lead to an inaccurate analysis. Determining the correct time a particular event occurred on a system is critical when condu...Rule Medium Severity -
SRG-APP-000373-NDM-000298
Group -
The Arista Multilayer Switch must be configured to synchronize internal information system clocks with the primary and secondary time sources located in different geographic regions using redundant authoritative time sources.
The loss of connectivity to a particular authoritative time source will result in the loss of time synchronization (free-run mode) and increasingly inaccurate time stamps on audit events and other ...Rule Medium Severity -
SRG-APP-000374-NDM-000299