Skip to content

Trend Micro TippingPoint NDM Security Technical Implementation Guide

Rules, Groups, and Values defined within the XCCDF Benchmark

  • The TippingPoint TPS must have FIPS Mode enforced.

    Unapproved mechanisms that are used for authentication to the cryptographic module are not validated and therefore cannot be relied upon to provide confidentiality or integrity, and DoD data may be...
    Rule High Severity
  • SRG-APP-000190-NDM-000267

    Group
  • SRG-APP-000142-NDM-000245

    Group
  • SRG-APP-000148-NDM-000346

    Group
  • The TippingPoint SMS must be configured with only one local account to be used as the account of last resort in the event the authentication server is unavailable.

    Authentication for administrative (privileged level) access to the device is required at all times. An account can be created on the device's local database for use when the authentication server i...
    Rule Medium Severity
  • SRG-APP-000164-NDM-000252

    Group
  • The TippingPoint SMS must enforce a minimum 15-character password length.

    Password complexity, or strength, is a measure of the effectiveness of a password in resisting attempts at guessing and brute-force attacks. Password length is one factor of several that helps to d...
    Rule Medium Severity
  • SRG-APP-000166-NDM-000254

    Group
  • SRG-APP-000167-NDM-000255

    Group
  • The TippingPoint SMS must enforce password complexity by requiring that at least one lowercase character be used.

    Use of a complex password helps to increase the time and resources required to compromise the password. Password complexity, or strength, is a measure of the effectiveness of a password in resistin...
    Rule Medium Severity
  • SRG-APP-000168-NDM-000256

    Group
  • The TippingPoint SMS must enforce password complexity by requiring that at least one numeric character be used.

    Use of a complex password helps to increase the time and resources required to compromise the password. Password complexity, or strength, is a measure of the effectiveness of a password in resistin...
    Rule Medium Severity
  • SRG-APP-000169-NDM-000257

    Group
  • SRG-APP-000179-NDM-000265

    Group
  • SRG-APP-000360-NDM-000295

    Group
  • The Trend Micro SMS must generate an alert for all audit failure events requiring real-time alerts.

    It is critical for the appropriate personnel to be aware if a system is at risk of failing to process audit logs as required. Without a real-time alert, security personnel may be unaware of an impe...
    Rule Medium Severity
  • SRG-APP-000373-NDM-000298

    Group
  • SRG-APP-000374-NDM-000299

    Group
  • The TippingPoint SMS must record time stamps for audit records that can be mapped to Coordinated Universal Time (UTC) or Greenwich Mean Time (GMT).

    If time stamps are not consistently applied and there is no common time reference, it is difficult to perform forensic analysis. Time stamps generated by the application include date and time. Tim...
    Rule Medium Severity
  • SRG-APP-000380-NDM-000304

    Group

The content of the drawer really is up to you. It could have form fields, definition lists, text lists, labels, charts, progress bars, etc. Spacing recommendation is 24px margins. You can put tabs in here, and can also make the drawer scrollable.