Router Security Requirements Guide
Rules, Groups, and Values defined within the XCCDF Benchmark
-
SRG-NET-000362
<GroupDescription></GroupDescription>Group -
The router must be configured to stop forwarding traffic upon the failure of the following actions: system initialization, shutdown, or system abort.
<VulnDiscussion>Failure to a known safe state helps prevent systems from failing to a state that may cause loss of data or unauthorized acces...Rule Medium Severity -
SRG-NET-000343
<GroupDescription></GroupDescription>Group -
The PE router providing MPLS Layer 2 Virtual Private Network (L2VPN) services must be configured to authenticate targeted Label Distribution Protocol (LDP) sessions used to exchange virtual circuit (VC) information using a FIPS-approved message authentication code algorithm.
<VulnDiscussion>LDP provides the signaling required for setting up and tearing down pseudowires (virtual circuits used to transport Layer 2 f...Rule Medium Severity -
SRG-NET-000343
<GroupDescription></GroupDescription>Group -
The Multicast Source Discovery Protocol (MSDP) router must be configured to authenticate all received MSDP packets.
<VulnDiscussion>MSDP peering with customer network routers presents additional risks to the core, whether from a rogue or misconfigured MSDP-...Rule Medium Severity -
SRG-NET-000362
<GroupDescription></GroupDescription>Group -
The router must not be configured to have any zero-touch deployment feature enabled when connected to an operational network.
<VulnDiscussion>Network devices that are configured via a zero-touch deployment or auto-loading feature can have their startup configuration ...Rule Medium Severity -
SRG-NET-000362
<GroupDescription></GroupDescription>Group -
The router must be configured to protect against or limit the effects of denial-of-service (DoS) attacks by employing control plane protection.
<VulnDiscussion>The Route Processor (RP) is critical to all network operations because it is the component used to build all forwarding paths...Rule Medium Severity
Node 2
The content of the drawer really is up to you. It could have form fields, definition lists, text lists, labels, charts, progress bars, etc. Spacing recommendation is 24px margins. You can put tabs in here, and can also make the drawer scrollable.