Network Device Management Security Requirements Guide

Rules, Groups, and Values defined within the XCCDF Benchmark

  • The network device must be configured to assign appropriate user roles or access levels to authenticated users.

    <VulnDiscussion>Successful identification and authentication must not automatically give an entity full access to a network device or securit...
    Rule High Severity
  • SRG-APP-000038

    <GroupDescription></GroupDescription>
    Group
  • The network device must enforce approved authorizations for controlling the flow of management information within the network device based on information flow control policies.

    &lt;VulnDiscussion&gt;A mechanism to detect and prevent unauthorized communication flow must be configured or provided as part of the system design...
    Rule Medium Severity
  • SRG-APP-000065

    <GroupDescription></GroupDescription>
    Group
  • The network device must be configured to enforce the limit of three consecutive invalid logon attempts, after which time it must block any login attempt for 15 minutes.

    &lt;VulnDiscussion&gt;By limiting the number of failed login attempts, the risk of unauthorized system access via user password guessing, otherwise...
    Rule Medium Severity
  • SRG-APP-000068

    <GroupDescription></GroupDescription>
    Group
  • The network device must display the Standard Mandatory DoD Notice and Consent Banner before granting access to the device.

    &lt;VulnDiscussion&gt;Display of the DoD-approved use notification before granting access to the network device ensures privacy and security notifi...
    Rule Medium Severity
  • SRG-APP-000069

    <GroupDescription></GroupDescription>
    Group
  • The network device must retain the Standard Mandatory DoD Notice and Consent Banner on the screen until the administrator acknowledges the usage conditions and takes explicit actions to log on for further access.

    &lt;VulnDiscussion&gt;The banner must be acknowledged by the administrator prior to the device allowing the administrator access to the network dev...
    Rule Medium Severity
  • SRG-APP-000080

    <GroupDescription></GroupDescription>
    Group