MS SQL Server 2016 Instance Security Technical Implementation Guide

Rules, Groups, and Values defined within the XCCDF Benchmark

  • SRG-APP-000122-DB-000203

    <GroupDescription></GroupDescription>
    Group
  • SQL Server must protect its audit configuration from authorized and unauthorized access and modification.

    &lt;VulnDiscussion&gt;Protecting audit data also includes identifying and protecting the tools used to view and manipulate log data. Therefore, pro...
    Rule Medium Severity
  • SRG-APP-000133-DB-000179

    <GroupDescription></GroupDescription>
    Group
  • SQL Server must limit privileges to change software modules, to include stored procedures, functions and triggers, and links to software external to SQL Server.

    &lt;VulnDiscussion&gt;If the system were to allow any user to make changes to software libraries, then those changes might be implemented without u...
    Rule Medium Severity
  • SRG-APP-000133-DB-000198

    <GroupDescription></GroupDescription>
    Group
  • SQL Server software installation account must be restricted to authorized users.

    &lt;VulnDiscussion&gt;When dealing with change control issues, it should be noted any changes to the hardware, software, and/or firmware components...
    Rule High Severity
  • SRG-APP-000133-DB-000199

    <GroupDescription></GroupDescription>
    Group
  • Database software, including DBMS configuration files, must be stored in dedicated directories, separate from the host OS and other applications.

    &lt;VulnDiscussion&gt;When dealing with change control issues, it should be noted any changes to the hardware, software, and/or firmware components...
    Rule Medium Severity
  • SRG-APP-000141-DB-000090

    <GroupDescription></GroupDescription>
    Group
  • Default demonstration and sample databases, database objects, and applications must be removed.

    &lt;VulnDiscussion&gt;Information systems are capable of providing a wide variety of functions and services. Some of the functions and services, pr...
    Rule Medium Severity