Skip to content

MarkLogic Server v9 Security Technical Implementation Guide

Rules, Groups, and Values defined within the XCCDF Benchmark

  • SRG-APP-000123-DB-000204

    <GroupDescription></GroupDescription>
    Group
  • MarkLogic Server must protect its audit features from unauthorized removal.

    &lt;VulnDiscussion&gt;Protecting audit data also includes identifying and protecting the tools used to view and manipulate log data. Therefore, pro...
    Rule Medium Severity
  • SRG-APP-000133-DB-000179

    <GroupDescription></GroupDescription>
    Group
  • MarkLogic Server must limit privileges to change software modules, including stored procedures, functions, and triggers, and links to software external to the DBMS.

    &lt;VulnDiscussion&gt;If the system were to allow any user to make changes to software libraries, then those changes might be implemented without u...
    Rule Medium Severity
  • SRG-APP-000133-DB-000198

    <GroupDescription></GroupDescription>
    Group
  • Unused database components, DBMS software, and database objects must be removed.

    &lt;VulnDiscussion&gt;Information systems are capable of providing a wide variety of functions and services. Some of the functions and services, pr...
    Rule Medium Severity
  • SRG-APP-000141-DB-000093

    <GroupDescription></GroupDescription>
    Group
  • MarkLogic Server software installation account must be restricted to authorized users.

    &lt;VulnDiscussion&gt;When dealing with change control issues, it should be noted any changes to the hardware, software, and/or firmware components...
    Rule Medium Severity
  • SRG-APP-000133-DB-000199

    <GroupDescription></GroupDescription>
    Group
  • MarkLogic Server software, including configuration files, must be stored in dedicated directories, or DASD pools, separate from the host OS and other applications.

    &lt;VulnDiscussion&gt;When dealing with change control issues, it should be noted any changes to the hardware, software, and/or firmware components...
    Rule Medium Severity