Skip to content

Central Log Server Security Requirements Guide

Rules, Groups, and Values defined within the XCCDF Benchmark

  • SRG-APP-000369

    <GroupDescription></GroupDescription>
    Group
  • The Central Log Server must be configured to perform audit reduction that does not alter original content or time ordering of log records.

    &lt;VulnDiscussion&gt;If the audit reduction capability alters the content or time ordering of log records, the integrity of the log records is com...
    Rule Low Severity
  • SRG-APP-000370

    <GroupDescription></GroupDescription>
    Group
  • SRG-APP-000375

    <GroupDescription></GroupDescription>
    Group
  • The Central Log Server must be configured to record time stamps for when log records are received by the log server that meet a granularity of one second for a minimum degree of precision.

    &lt;VulnDiscussion&gt;Without sufficient granularity of time stamps, it is not possible to adequately determine the chronological order of records....
    Rule Low Severity