Skip to content

Application Security and Development Security Technical Implementation Guide

Rules, Groups, and Values defined within the XCCDF Benchmark

  • The application must log user actions involving access to data.

    <VulnDiscussion>When users access application data, there is risk of data compromise or seepage if the account used to access is compromised ...
    Rule Medium Severity
  • SRG-APP-000095

    <GroupDescription></GroupDescription>
    Group
  • The application must log user actions involving changes to data.

    &lt;VulnDiscussion&gt;When users change/modify application data, there is risk of data compromise if the account used to access is compromised or a...
    Rule Medium Severity
  • SRG-APP-000096

    <GroupDescription></GroupDescription>
    Group
  • The application must produce audit records containing information to establish when (date and time) the events occurred.

    &lt;VulnDiscussion&gt;Without establishing when events occurred, it is impossible to establish, correlate, and investigate the events relating to a...
    Rule Medium Severity