Arista MLS EOS 4.2x Router Security Technical Implementation Guide

Rules, Groups, and Values defined within the XCCDF Benchmark

  • The Arista router must be configured to produce audit records containing information to establish where the events occurred.

    Without establishing where events occurred, it is impossible to establish, correlate, and investigate the events leading up to an outage or attack. In order to compile an accurate risk assessment ...
    Rule Medium Severity
  • The MPLS router with RSVP-TE enabled must be configured with message pacing or refresh reduction to adjust maximum number of RSVP messages to an output queue based on the link speed and input queue size of adjacent core routers.

    RSVP-TE can be used to perform constraint-based routing when building LSP tunnels within the network core that will support QoS and traffic engineering requirements. RSVP-TE is also used to enable ...
    Rule Low Severity
  • The Arista perimeter router must be configured to deny network traffic by default and allow network traffic by exception.

    A deny-all, permit-by-exception network communications traffic policy ensures that only connections that are essential and approved are allowed. This requirement applies to both inbound and outbou...
    Rule High Severity
  • The Arista router must be configured to block any traffic that is destined to IP core infrastructure.

    IP/MPLS networks providing VPN and transit services must provide, at the least, the same level of protection against denial-of-service (DoS) attacks and intrusions as Layer 2 networks. Although the...
    Rule High Severity
  • The Arista router must be configured to only permit management traffic that ingresses and egresses the out-of-band management (OOBM) interface.

    The OOBM access router will connect to the management interface of the managed network elements. The management interface can be a true OOBM interface or a standard interface functioning as the man...
    Rule Medium Severity

The content of the drawer really is up to you. It could have form fields, definition lists, text lists, labels, charts, progress bars, etc. Spacing recommendation is 24px margins. You can put tabs in here, and can also make the drawer scrollable.

Capacity