Arista MLS EOS 4.2x Router Security Technical Implementation Guide
Rules, Groups, and Values defined within the XCCDF Benchmark
-
SRG-NET-000019-RTR-000002
<GroupDescription></GroupDescription>Group -
The Arista perimeter router must be configured to enforce approved authorizations for controlling the flow of information between interconnected networks in accordance with applicable policy.
<VulnDiscussion>Information flow control regulates authorized information to travel within a network and between interconnected networks. Con...Rule Medium Severity -
SRG-NET-000019-RTR-000003
<GroupDescription></GroupDescription>Group -
The Arista multicast router must be configured to disable Protocol Independent Multicast (PIM) on all interfaces that are not required to support multicast routing.
<VulnDiscussion>If multicast traffic is forwarded beyond the intended boundary, it is possible that it can be intercepted by unauthorized or ...Rule Medium Severity -
SRG-NET-000019-RTR-000004
<GroupDescription></GroupDescription>Group -
The Arista multicast router must be configured to bind a Protocol Independent Multicast (PIM) neighbor filter to interfaces that have PIM enabled.
<VulnDiscussion>PIM is a routing protocol used to build multicast distribution trees for forwarding multicast traffic across the network infr...Rule Medium Severity -
SRG-NET-000019-RTR-000005
<GroupDescription></GroupDescription>Group -
The Arista multicast edge router must be configured to establish boundaries for administratively scoped multicast traffic.
<VulnDiscussion>If multicast traffic is forwarded beyond the intended boundary, it is possible that it can be intercepted by unauthorized or ...Rule Low Severity -
SRG-NET-000019-RTR-000007
<GroupDescription></GroupDescription>Group -
The Arista router must be configured to have all inactive interfaces disabled.
<VulnDiscussion>An inactive interface is rarely monitored or controlled and may expose a network to an undetected attack on that interface. U...Rule Low Severity
Node 2
The content of the drawer really is up to you. It could have form fields, definition lists, text lists, labels, charts, progress bars, etc. Spacing recommendation is 24px margins. You can put tabs in here, and can also make the drawer scrollable.