Skip to content

Application Layer Gateway Security Requirements Guide

Rules, Groups, and Values defined within the XCCDF Benchmark

  • SRG-NET-000521

    <GroupDescription></GroupDescription>
    Group
  • The ALG providing user access control intermediary services must conceal, via the session lock, information previously visible on the display with a publicly viewable image.

    &lt;VulnDiscussion&gt;A session time-out lock is a temporary action taken when a user stops work and moves away from the immediate physical vicinit...
    Rule Medium Severity
  • SRG-NET-000700

    <GroupDescription></GroupDescription>
    Group
  • The ALG must prevent or restrict changes to the configuration of the system under organization-defined circumstances.

    &lt;VulnDiscussion&gt;System configuration changes can adversely affect critical system security and privacy functionality. Change restrictions can...
    Rule Medium Severity
  • SRG-NET-000705

    <GroupDescription></GroupDescription>
    Group
  • The ALG must employ organization-defined controls by type of denial of service (DoS) to achieve the DoS objective.

    &lt;VulnDiscussion&gt;DoS events can occur due to a variety of internal and external causes, such as an attack by an adversary or a lack of plannin...
    Rule Medium Severity
  • SRG-NET-000715

    <GroupDescription></GroupDescription>
    Group
  • The ALG must implement physically or logically separate subnetworks to isolate organization-defined critical system components and functions.

    &lt;VulnDiscussion&gt;Separating critical system components and functions from other noncritical system components and functions through separate s...
    Rule Medium Severity
  • SRG-NET-000735

    <GroupDescription></GroupDescription>
    Group
  • The ALG must include only approved trust anchors in trust stores or certificate stores managed by the organization.

    &lt;VulnDiscussion&gt;Public key infrastructure (PKI) certificates are certificates with visibility external to organizational systems and certific...
    Rule Medium Severity