CA API Gateway ALG Security Technical Implementation Guide
Rules, Groups, and Values defined within the XCCDF Benchmark
-
The CA API Gateway that provides intermediary services for TLS must be configured to comply with the required TLS settings in NIST SP 800-52.
<VulnDiscussion>SP 800-52 provides guidance on using the most secure version and configuration of the TLS/SSL protocol. Using older unauthori...Rule Medium Severity -
SRG-NET-000063-ALG-000012
<GroupDescription></GroupDescription>Group -
The CA API Gateway providing intermediary services for remote access communications traffic must use NIST FIPS-validated cryptography to protect the integrity of remote access sessions.
<VulnDiscussion>Without cryptographic integrity protections, information can be altered by unauthorized users without detection. Remote acce...Rule Medium Severity -
SRG-NET-000077-ALG-000046
<GroupDescription></GroupDescription>Group -
The CA API Gateway must produce audit records containing information to establish the source of the events.
<VulnDiscussion>Without establishing the source of the event, it is impossible to establish, correlate, and investigate the events leading up...Rule Medium Severity -
SRG-NET-000078-ALG-000047
<GroupDescription></GroupDescription>Group -
The CA API Gateway must produce audit records containing information to establish the outcome of the events.
<VulnDiscussion>Without information about the outcome of events, security personnel cannot make an accurate assessment as to whether an attac...Rule Medium Severity -
SRG-NET-000079-ALG-000048
<GroupDescription></GroupDescription>Group -
The CA API Gateway must generate audit records containing information to establish the identity of any individual or process associated with the event.
<VulnDiscussion>Without information that establishes the identity of the subjects (i.e., users or processes acting on behalf of users) associ...Rule Medium Severity -
SRG-NET-000098-ALG-000056
<GroupDescription></GroupDescription>Group
Node 2
The content of the drawer really is up to you. It could have form fields, definition lists, text lists, labels, charts, progress bars, etc. Spacing recommendation is 24px margins. You can put tabs in here, and can also make the drawer scrollable.