F5 BIG-IP Device Management Security Technical Implementation Guide

Rules, Groups, and Values defined within the XCCDF Benchmark

  • SRG-APP-000167-NDM-000255

    <GroupDescription></GroupDescription>
    Group
  • If multifactor authentication is not supported and passwords must be used, the BIG-IP appliance must enforce password complexity by requiring that at least one lower-case character be used.

    &lt;VulnDiscussion&gt;Use of a complex password helps to increase the time and resources required to compromise the password. Password complexity, ...
    Rule Medium Severity
  • SRG-APP-000168-NDM-000256

    <GroupDescription></GroupDescription>
    Group
  • If multifactor authentication is not supported and passwords must be used, the BIG-IP appliance must enforce password complexity by requiring that at least one numeric character be used.

    &lt;VulnDiscussion&gt;Use of a complex password helps to increase the time and resources required to compromise the password. Password complexity, ...
    Rule Medium Severity
  • SRG-APP-000169-NDM-000257

    <GroupDescription></GroupDescription>
    Group
  • The BIG-IP appliance must be configured to enforce organization-defined role-based access control policies over defined subjects and objects.

    &lt;VulnDiscussion&gt;Organizations can create specific roles based on job functions and the authorizations (i.e., privileges) to perform needed op...
    Rule Medium Severity
  • SRG-APP-000357-NDM-000293

    <GroupDescription></GroupDescription>
    Group
  • The BIG-IP appliance must be configured to allocate audit record storage capacity in accordance with organization-defined audit record storage requirements.

    &lt;VulnDiscussion&gt;In order to ensure network devices have a sufficient storage capacity in which to write the audit logs, they need to be able ...
    Rule Medium Severity
  • SRG-APP-000373-NDM-000298

    <GroupDescription></GroupDescription>
    Group
  • The BIG-IP appliance must be configured to synchronize internal information system clocks with the primary and secondary time sources located in different geographic regions using redundant authoritative time sources.

    &lt;VulnDiscussion&gt;The loss of connectivity to a particular authoritative time source will result in the loss of time synchronization (free-run ...
    Rule Medium Severity