Red Hat Enterprise Linux 7 Security Technical Implementation Guide
Rules, Groups, and Values defined within the XCCDF Benchmark
-
SRG-OS-000163-GPOS-00072
<GroupDescription></GroupDescription>Group -
The Red Hat Enterprise Linux operating system must be configured so that all network connections associated with SSH traffic terminate after becoming unresponsive.
<VulnDiscussion>Terminating an unresponsive SSH session within a short time period reduces the window of opportunity for unauthorized personn...Rule Medium Severity -
SRG-OS-000480-GPOS-00227
<GroupDescription></GroupDescription>Group -
The Red Hat Enterprise Linux operating system must be configured so that the SSH daemon does not allow authentication using rhosts authentication.
<VulnDiscussion>Configuring this setting for the SSH daemon provides additional assurance that remote logon via SSH will require a password, ...Rule Medium Severity -
SRG-OS-000480-GPOS-00227
<GroupDescription></GroupDescription>Group -
The Red Hat Enterprise Linux operating system must display the date and time of the last successful account logon upon an SSH logon.
<VulnDiscussion>Providing users with feedback on when account accesses via SSH last occurred facilitates user recognition and reporting of un...Rule Medium Severity -
SRG-OS-000480-GPOS-00227
<GroupDescription></GroupDescription>Group -
The Red Hat Enterprise Linux operating system must not permit direct logons to the root account using remote access via SSH.
<VulnDiscussion>Even though the communications channel may be encrypted, an additional layer of security is gained by extending the policy of...Rule Medium Severity -
SRG-OS-000480-GPOS-00227
<GroupDescription></GroupDescription>Group -
The Red Hat Enterprise Linux operating system must be configured so that the SSH daemon does not allow authentication using known hosts authentication.
<VulnDiscussion>Configuring this setting for the SSH daemon provides additional assurance that remote logon via SSH will require a password, ...Rule Medium Severity
Node 2