Skip to content

Microsoft Windows Server 2019 Security Technical Implementation Guide

Rules, Groups, and Values defined within the XCCDF Benchmark

  • SRG-OS-000062-GPOS-00031

    <GroupDescription></GroupDescription>
    Group
  • Windows Server 2019 must force audit policy subcategory settings to override audit policy category settings.

    &lt;VulnDiscussion&gt;Maintaining an audit trail of system activity logs can help identify configuration errors, troubleshoot service disruptions, ...
    Rule Medium Severity
  • SRG-OS-000066-GPOS-00034

    <GroupDescription></GroupDescription>
    Group
  • Windows Server 2019 domain controllers must have a PKI server certificate.

    &lt;VulnDiscussion&gt;Domain controllers are part of the chain of trust for PKI authentications. Without the appropriate certificate, the authentic...
    Rule Medium Severity
  • SRG-OS-000066-GPOS-00034

    <GroupDescription></GroupDescription>
    Group
  • Windows Server 2019 domain Controller PKI certificates must be issued by the DoD PKI or an approved External Certificate Authority (ECA).

    &lt;VulnDiscussion&gt;A PKI implementation depends on the practices established by the Certificate Authority (CA) to ensure the implementation is s...
    Rule High Severity
  • SRG-OS-000066-GPOS-00034

    <GroupDescription></GroupDescription>
    Group
  • Windows Server 2019 PKI certificates associated with user accounts must be issued by a DoD PKI or an approved External Certificate Authority (ECA).

    &lt;VulnDiscussion&gt;A PKI implementation depends on the practices established by the Certificate Authority (CA) to ensure the implementation is s...
    Rule High Severity
  • SRG-OS-000066-GPOS-00034

    <GroupDescription></GroupDescription>
    Group
  • Windows Server 2019 must have the DoD Root Certificate Authority (CA) certificates installed in the Trusted Root Store.

    &lt;VulnDiscussion&gt;To ensure secure DoD websites and DoD-signed code are properly validated, the system must trust the DoD Root CAs. The DoD roo...
    Rule Medium Severity