Microsoft Windows Server 2019 Security Technical Implementation Guide

Rules, Groups, and Values defined within the XCCDF Benchmark

  • SRG-OS-000021-GPOS-00005

    <GroupDescription></GroupDescription>
    Group
  • Windows Server 2019 must have the number of allowed bad logon attempts configured to three or less.

    &lt;VulnDiscussion&gt;The account lockout feature, when enabled, prevents brute-force password attacks on the system. The higher this value is, the...
    Rule Medium Severity
  • SRG-OS-000021-GPOS-00005

    <GroupDescription></GroupDescription>
    Group
  • Windows Server 2019 must have the period of time before the bad logon counter is reset configured to 15 minutes or greater.

    &lt;VulnDiscussion&gt;The account lockout feature, when enabled, prevents brute-force password attacks on the system. This parameter specifies the ...
    Rule Medium Severity
  • SRG-OS-000023-GPOS-00006

    <GroupDescription></GroupDescription>
    Group
  • Windows Server 2019 required legal notice must be configured to display before console logon.

    &lt;VulnDiscussion&gt;Failure to display the logon banner prior to a logon attempt will negate legal proceedings resulting from unauthorized access...
    Rule Medium Severity
  • SRG-OS-000023-GPOS-00006

    <GroupDescription></GroupDescription>
    Group
  • Windows Server 2019 title for legal banner dialog box must be configured with the appropriate text.

    &lt;VulnDiscussion&gt;Failure to display the logon banner prior to a logon attempt will negate legal proceedings resulting from unauthorized access...
    Rule Low Severity
  • SRG-OS-000028-GPOS-00009

    <GroupDescription></GroupDescription>
    Group
  • Windows Server 2019 machine inactivity limit must be set to 15 minutes or less, locking the system with the screen saver.

    &lt;VulnDiscussion&gt;Unattended systems are susceptible to unauthorized use and should be locked when unattended. The screen saver should be set a...
    Rule Medium Severity