Microsoft Windows Server 2016 Security Technical Implementation Guide
Rules, Groups, and Values defined within the XCCDF Benchmark
-
SRG-OS-000073-GPOS-00041
<GroupDescription></GroupDescription>Group -
Windows Server 2016 reversible password encryption must be disabled.
<VulnDiscussion>Storing passwords using reversible encryption is essentially the same as storing clear-text versions of the passwords, which ...Rule High Severity -
SRG-OS-000342-GPOS-00133
<GroupDescription></GroupDescription>Group -
Audit records must be backed up to a different system or media than the system being audited.
<VulnDiscussion>Protection of log data includes assuring the log data is not accidentally lost or deleted. Audit information stored in one lo...Rule Medium Severity -
SRG-OS-000479-GPOS-00224
<GroupDescription></GroupDescription>Group
Node 2
The content of the drawer really is up to you. It could have form fields, definition lists, text lists, labels, charts, progress bars, etc. Spacing recommendation is 24px margins. You can put tabs in here, and can also make the drawer scrollable.
Capacity
Modules