Skip to content

MS SQL Server 2016 Database Security Technical Implementation Guide

Rules, Groups, and Values defined within the XCCDF Benchmark

  • SRG-APP-000314-DB-000310

    <GroupDescription></GroupDescription>
    Group
  • SQL Server must associate organization-defined types of security labels having organization-defined security label values with information in transmission.

    &lt;VulnDiscussion&gt;Without the association of security labels to information, there is no basis for SQL Server to make security-related access-c...
    Rule Medium Severity
  • SRG-APP-000328-DB-000301

    <GroupDescription></GroupDescription>
    Group
  • SQL Server must enforce discretionary access control policies, as defined by the data owner, over defined subjects and objects.

    &lt;VulnDiscussion&gt;Discretionary Access Control (DAC) is based on the notion that individual users are "owners" of objects and therefore have di...
    Rule Low Severity
  • SRG-APP-000342-DB-000302

    <GroupDescription></GroupDescription>
    Group
  • Execution of stored procedures and functions that utilize execute as must be restricted to necessary cases only.

    &lt;VulnDiscussion&gt;In certain situations, to provide required functionality, a DBMS needs to execute internal logic (stored procedures, function...
    Rule Medium Severity
  • SRG-APP-000378-DB-000365

    <GroupDescription></GroupDescription>
    Group
  • SQL Server must prohibit user installation of logic modules (stored procedures, functions, triggers, views, etc.) without explicit privileged status.

    &lt;VulnDiscussion&gt;Allowing regular users to install software, without explicit privileges, creates the risk that untested or potentially malici...
    Rule Medium Severity
  • SRG-APP-000380-DB-000360

    <GroupDescription></GroupDescription>
    Group
  • SQL Server must enforce access restrictions associated with changes to the configuration of the database(s).

    &lt;VulnDiscussion&gt;Failure to provide logical access restrictions associated with changes to configuration may have significant effects on the o...
    Rule Medium Severity