A10 Networks ADC ALG Security Technical Implementation Guide

Rules, Groups, and Values defined within the XCCDF Benchmark

  • The A10 Networks ADC must be configured to prohibit or restrict the use of functions, ports, protocols, and/or services as defined in the PPSM CAL and vulnerability assessments.

    <VulnDiscussion>In order to prevent unauthorized connection of devices, unauthorized transfer of information, or unauthorized tunneling (i.e....
    Rule Medium Severity
  • SRG-NET-000164-ALG-000100

    <GroupDescription></GroupDescription>
    Group
  • The A10 Networks ADC when used for TLS encryption and decryption must validate certificates used for TLS functions by performing RFC 5280-compliant certification path validation.

    &lt;VulnDiscussion&gt;A certificate's certification path is the path from the end entity certificate to a trusted root certification authority (CA)...
    Rule Medium Severity
  • SRG-NET-000202-ALG-000124

    <GroupDescription></GroupDescription>
    Group
  • The A10 Networks ADC must not have any unnecessary or unapproved virtual servers configured.

    &lt;VulnDiscussion&gt;A deny-all, permit-by-exception network communications traffic policy ensures that only those connections which are essential...
    Rule Medium Severity
  • SRG-NET-000273-ALG-000129

    <GroupDescription></GroupDescription>
    Group
  • The A10 Networks ADC, when used to load balance web applications, must strip HTTP response headers.

    &lt;VulnDiscussion&gt;Providing too much information in error messages risks compromising the data and security of the application and system. HTTP...
    Rule Medium Severity
  • SRG-NET-000273-ALG-000129

    <GroupDescription></GroupDescription>
    Group
  • The A10 Networks ADC, when used to load balance web applications, must replace response codes.

    &lt;VulnDiscussion&gt;Providing too much information in error messages risks compromising the data and security of the application and system. HTTP...
    Rule Medium Severity
  • SRG-NET-000318-ALG-000014

    <GroupDescription></GroupDescription>
    Group