Skip to content

Tanium 7.x Application on TanOS Security Technical Implementation Guide

Rules, Groups, and Values defined within the XCCDF Benchmark

  • The Tanium cryptographic signing capabilities must be enabled on the Tanium Clients to safeguard the authenticity of communications sessions when answering requests from the Tanium Server.

    <VulnDiscussion>All of Tanium's signing capabilities should be enabled upon install. Tanium supports the cryptographic signing and verificati...
    Rule Medium Severity
  • SRG-APP-000131

    <GroupDescription></GroupDescription>
    Group
  • The Tanium cryptographic signing capabilities must be enabled on the Tanium Server.

    &lt;VulnDiscussion&gt;All of Tanium's signing capabilities must be enabled upon install. Tanium supports the cryptographic signing and verification...
    Rule Medium Severity
  • SRG-APP-000142

    <GroupDescription></GroupDescription>
    Group
  • Firewall rules must be configured on the Tanium Endpoints for Client-to-Server communications.

    &lt;VulnDiscussion&gt;In addition to the client-to-server TCP communication that takes place over port 17472, Tanium Clients also communicate to ot...
    Rule Medium Severity
  • SRG-APP-000142

    <GroupDescription></GroupDescription>
    Group
  • Firewall rules must be configured on the Tanium Server for Client-to-Server communications.

    &lt;VulnDiscussion&gt;In addition to the client-to-server TCP communication that takes place over port 17472, Tanium Clients also communicate to ot...
    Rule Medium Severity
  • SRG-APP-000142

    <GroupDescription></GroupDescription>
    Group
  • Firewall rules must be configured on the Tanium Zone Server for Client-to-Zone Server communications.

    &lt;VulnDiscussion&gt;In customer environments using the Tanium Zone Server, a Tanium Client may be configured to point to a Zone Server instead of...
    Rule Medium Severity
  • SRG-APP-000142

    <GroupDescription></GroupDescription>
    Group