Symantec ProxySG NDM Security Technical Implementation Guide
Rules, Groups, and Values defined within the XCCDF Benchmark
-
SRG-APP-000360-NDM-000295
<GroupDescription></GroupDescription>Group -
Symantec ProxySG must generate an alert to the console when a log processing failure is detected such as loss of communications with the Central Log Server or log records are no longer being sent.
<VulnDiscussion>It is critical for the appropriate personnel to be aware if a system is at risk of failing to process audit logs as required....Rule Low Severity -
SRG-APP-000371-NDM-000296
<GroupDescription></GroupDescription>Group -
Symantec ProxySG must compare internal information system clocks at least every 24 hours with an authoritative time server.
<VulnDiscussion>Inaccurate time stamps make it more difficult to correlate events and can lead to an inaccurate analysis. Determining the cor...Rule Medium Severity -
SRG-APP-000373-NDM-000298
<GroupDescription></GroupDescription>Group -
Symantec ProxySG must be configured to synchronize internal information system clocks with the primary and secondary time sources located in different geographic regions using redundant authoritative time sources.
<VulnDiscussion>The loss of connectivity to a particular authoritative time source will result in the loss of time synchronization (free-run ...Rule Medium Severity -
SRG-APP-000122-NDM-000239
<GroupDescription></GroupDescription>Group -
Symantec ProxySG must use Role-Based Access Control (RBAC) to assign privileges to users for access to files and functions.
<VulnDiscussion>Organizations can create specific roles based on job functions and the authorizations (i.e., privileges) to perform needed op...Rule Medium Severity -
SRG-APP-000516-NDM-000337
<GroupDescription></GroupDescription>Group -
Symantec ProxySG must employ automated mechanisms to centrally apply authentication settings.
<VulnDiscussion>The use of authentication servers or other centralized management servers for providing centralized authentication services i...Rule Medium Severity