Skip to content

Tanium 7.0 Security Technical Implementation Guide

Rules, Groups, and Values defined within the XCCDF Benchmark

  • SRG-APP-000149

    <GroupDescription></GroupDescription>
    Group
  • Common Access Card (CAC)-based authentication must be enforced and enabled on the Tanium Server for network and local access with privileged and non-privileged accounts.

    &lt;VulnDiscussion&gt;To assure accountability and prevent unauthenticated access, organizational users must be identified and authenticated to pre...
    Rule High Severity
  • SRG-APP-000383

    <GroupDescription></GroupDescription>
    Group
  • Firewall rules must be configured on the Tanium Server for Console-to-Server communications.

    &lt;VulnDiscussion&gt;An HTML5 based application, the Tanium Console runs from any device with a browser that supports HTML5. For security, the HTT...
    Rule Medium Severity
  • SRG-APP-000070

    <GroupDescription></GroupDescription>
    Group
  • The publicly accessible Tanium application must display the Standard Mandatory DoD Notice and Consent Banner before granting access to the application.

    &lt;VulnDiscussion&gt;Display of a standardized and approved use notification before granting access to the publicly accessible application ensures...
    Rule Medium Severity
  • SRG-APP-000108

    <GroupDescription></GroupDescription>
    Group
  • Tanium must alert the ISSO and SA (at a minimum) in the event of an audit processing failure.

    &lt;VulnDiscussion&gt;It is critical for the appropriate personnel to be aware if a system is at risk of failing to process audit logs as required....
    Rule Medium Severity
  • SRG-APP-000270

    <GroupDescription></GroupDescription>
    Group
  • Flaw remediation Tanium applications must employ automated mechanisms to determine the state of information system components with regard to flaw remediation using the following frequency: continuously, where HBSS is used; 30 days, for any additional internal network scans not covered by HBSS; and annually, for external scans by Computer Network Defense Service Provider (CNDSP).

    &lt;VulnDiscussion&gt;Without the use of automated mechanisms to scan for security flaws on a continuous and/or periodic basis, the system componen...
    Rule Medium Severity
  • SRG-APP-000291

    <GroupDescription></GroupDescription>
    Group
  • Tanium must notify system administrators and ISSO when accounts are created.

    &lt;VulnDiscussion&gt;Once an attacker establishes initial access to a system, the attacker often attempts to create a persistent method of re-esta...
    Rule Medium Severity
  • SRG-APP-000292

    <GroupDescription></GroupDescription>
    Group
  • SRG-APP-000175

    <GroupDescription></GroupDescription>
    Group
  • Tanium must notify system administrators and ISSO when accounts are modified.

    &lt;VulnDiscussion&gt;Once an attacker establishes initial access to a system, the attacker often attempts to create a persistent method of re-esta...
    Rule Medium Severity
  • SRG-APP-000320

    <GroupDescription></GroupDescription>
    Group
  • Tanium must notify the SA and ISSO of account enabling actions.

    &lt;VulnDiscussion&gt;Once an attacker establishes initial access to a system, the attacker often attempts to create a persistent method of re-esta...
    Rule Medium Severity
  • SRG-APP-000359

    <GroupDescription></GroupDescription>
    Group
  • Tanium must provide an immediate warning to the SA and ISSO (at a minimum) when allocated audit record storage volume reaches 75 percent of repository maximum audit record storage capacity.

    &lt;VulnDiscussion&gt;If security personnel are not notified immediately upon storage volume utilization reaching 75 percent, they are unable to pl...
    Rule Medium Severity
  • SRG-APP-000148

    <GroupDescription></GroupDescription>
    Group