Oracle HTTP Server 12.1.3 Security Technical Implementation Guide

Rules, Groups, and Values defined within the XCCDF Benchmark

  • OHS must have the OraLogSeverity directive defined to generate adequate information to be used by external applications or entities to monitor and control remote access.

    Remote access to the web server is any access that communicates through an external, non-organization-controlled network. Remote access can be used to access hosted applications or to perform manag...
    Rule Medium Severity
  • OHS must have a log format defined to generate adequate information to be used by external applications or entities to monitor and control remote access.

    Remote access to the web server is any access that communicates through an external, non-organization-controlled network. Remote access can be used to access hosted applications or to perform manag...
    Rule Medium Severity
  • OHS must have a log file defined for each site/virtual host to capture information to be used by external applications or entities to monitor and control remote access.

    Remote access to the web server is any access that communicates through an external, non-organization-controlled network. Remote access can be used to access hosted applications or to perform manag...
    Rule Medium Severity
  • OHS must have the Order, Allow, and Deny directives set within the Directory directives set to restrict inbound connections from nonsecure zones.

    Remote access to the web server is any access that communicates through an external, non-organization-controlled network. Remote access can be used to access hosted applications or to perform manag...
    Rule Medium Severity
  • OHS must provide the capability to immediately disconnect or disable remote access to the hosted applications.

    During an attack on the web server or any of the hosted applications, the system administrator may need to disconnect or disable access by users to stop the attack. The web server must provide a ...
    Rule Medium Severity