Guide to the Secure Configuration of Red Hat Enterprise Linux CoreOS 4
Rules, Groups, and Values defined within the XCCDF Benchmark
-
Vendor Approved Time Servers
The list of vendor-approved time serversValue -
Maximum NTP or Chrony Poll
The maximum NTP or Chrony poll interval number in seconds specified as a power of two.Value -
Install the ntp service
The ntpd service should be installed.Rule High Severity -
Disable chrony daemon from acting as server
The <code>port</code> option in <code>/etc/chrony.conf</code> can be set to <code>0</code> to make chrony daemon to never open any listening port for server operation and to operate strictly in a c...Rule Low Severity -
Disable network management of chrony daemon
Thecmdport
option in/etc/chrony.conf
can be set to0
to stop chrony daemon from listening on the UDP port 323 for management connections made by chronyc.Rule Low Severity -
Configure Time Service Maxpoll Interval
The <code>maxpoll</code> should be configured to <xccdf-1.2:sub idref="xccdf_org.ssgproject.content_value_var_time_service_set_maxpoll" use="legacy"></xccdf-1.2:sub> in <code>/etc/ntp.conf</code> o...Rule Medium Severity -
Specify a Remote NTP Server
Depending on specific functional requirements of a concrete production environment, the Red Hat Enterprise Linux CoreOS 4 system can be configured to utilize the services of the <code>chronyd</code...Rule Medium Severity -
Ensure Chrony is only configured with the server directive
Check that Chrony only has time sources configured with theserver
directive.Rule Medium Severity -
Specify Additional Remote NTP Servers
Additional NTP servers can be specified for time synchronization in the file <code>/etc/ntp.conf</code>. To do so, add additional lines of the following form, substituting the IP address or hostna...Rule Unknown Severity -
Specify a Remote NTP Server
To specify a remote NTP server for time synchronization, edit the file <code>/etc/ntp.conf</code>. Add or correct the following lines, substituting the IP or hostname of a remote NTP server for <em...Rule Medium Severity