Guide to the Secure Configuration of Red Hat Enterprise Linux CoreOS 4
Rules, Groups, and Values defined within the XCCDF Benchmark
-
Verify Integrity with AIDE
AIDE conducts integrity checks by comparing information about files with previously-gathered information. Ideally, the AIDE database is created imm...Group -
Install AIDE
Theaide
package can be installed with the following command:$ sudo dnf install aide
Rule Medium Severity -
Build and Test AIDE Database
Run the following command to generate a new database: <pre>$ sudo /usr/sbin/aide --init</pre> By default, the database will be written to the fil...Rule Medium Severity -
Configure SSH to use System Crypto Policy
Crypto Policies provide a centralized control over crypto algorithms usage of many packages. SSH is supported by crypto policy, but the SSH configu...Rule Medium Severity -
Federal Information Processing Standard (FIPS)
The Federal Information Processing Standard (FIPS) is a computer security standard which is developed by the U.S. Government and industry working g...Group -
Install the dracut-fips Package
To enable FIPS, the system requires that the <code>dracut-fips</code> package be installed. The <code>dracut-fips</code> package can be installed w...Rule Medium Severity -
Enable Dracut FIPS Module
To enable FIPS mode, run the following command: <pre>fips-mode-setup --enable</pre> To enable FIPS, the system requires that the <code>fips</code> ...Rule High Severity -
Enable FIPS Mode
OpenShift has an installation-time flag that can enable FIPS mode for the cluster. The flag <pre>fips: true</pre> must be enabled at install time ...Rule High Severity -
Ensure '/etc/system-fips' exists
On a system where FIPS mode is enabled, <code>/etc/system-fips</code> must exist. To enable FIPS mode, run the following command: <pre>fips-mode-se...Rule High Severity -
Set kernel parameter 'crypto.fips_enabled' to 1
System running in FIPS mode is indicated by kernel parameter <code>'crypto.fips_enabled'</code>. This parameter should be set to <code>1</code> in ...Rule High Severity
Node 2
The content of the drawer really is up to you. It could have form fields, definition lists, text lists, labels, charts, progress bars, etc. Spacing recommendation is 24px margins. You can put tabs in here, and can also make the drawer scrollable.
Capacity
Modules