  • The Chrony package is installed

    System time should be synchronized between all systems in an environment. This is typically done by establishing an authoritative time server or se...
    Rule Medium Severity
  • Install the ntp service

    The ntpd service should be installed.
    Rule High Severity
  • Enable the NTP Daemon

    The ntpd service can be enabled with the following command:
    $ sudo systemctl enable ntpd.service
    Rule Medium Severity
  • Disable chrony daemon from acting as server

    The <code>port</code> option in <code>/etc/chrony.conf</code> can be set to <code>0</code> to make chrony daemon to never open any listening port f...
    Rule Low Severity
  • Disable network management of chrony daemon

    The <code>cmdport</code> option in <code>/etc/chrony.conf</code> can be set to <code>0</code> to stop chrony daemon from listening on the UDP port ...
    Rule Low Severity
  • Configure Time Service Maxpoll Interval

    The <code>maxpoll</code> should be configured to <xccdf-1.2:sub idref="xccdf_org.ssgproject.content_value_var_time_service_set_maxpoll" use="legacy...
    Rule Medium Severity
  • Ensure Chrony is only configured with the server directive

    Check that Chrony only has time sources configured with the server directive.
    Rule Medium Severity
  • A remote time server for Chrony is configured

    <code>Chrony</code> is a daemon which implements the Network Time Protocol (NTP). It is designed to synchronize system clocks across a variety of s...
    Rule Medium Severity
  • Obsolete Services

    This section discusses a number of network-visible services which have historically caused problems for system security, and for which disabling or...
    Group
  • Xinetd

    The <code>xinetd</code> service acts as a dedicated listener for some network services (mostly, obsolete ones) and can be used to provide access co...
    Group