  • The Sentry must restrict or block harmful or suspicious communications traffic by controlling the flow of information between interconnected networks based on attribute- and content-based inspection of the source, destination, headers, and/or content of the communications traffic.

    <VulnDiscussion>Information flow control regulates where information is allowed to travel within a network and between interconnected network...
    Rule Medium Severity
  • SRG-NET-000062-ALG-000011

    <GroupDescription></GroupDescription>
    Group
  • The Sentry providing intermediary services for remote access communications traffic must use encryption services that implement NIST FIPS-validated cryptography to protect the confidentiality of remote access sessions.

    &lt;VulnDiscussion&gt;Without confidentiality protection mechanisms, unauthorized individuals may gain access to sensitive information via a remote...
    Rule Medium Severity
  • SRG-NET-000062-ALG-000092

    <GroupDescription></GroupDescription>
    Group
  • If Sentry stores secret or private keys, it must use FIPS-approved key management technology and processes in the production and control of private/secret cryptographic keys.

    &lt;VulnDiscussion&gt;Private key data is used to prove that the entity presenting a public key certificate is the certificate's rightful owner. Co...