Skip to content

ISEC7 Sphere Security Technical Implementation Guide

Rules, Groups, and Values defined within the XCCDF Benchmark

  • Before establishing a local, remote, and/or network connection with any endpoint device, the ISEC7 EMM Suite must use a bidirectional authentication mechanism configured with a FIPS-validated Advanced Encryption Standard (AES) cipher block algorithm to authenticate with the device.

    <VulnDiscussion>Without device-to-device authentication, communications with malicious devices may be established. Bidirectional authenticati...
    Rule Medium Severity
  • SRG-APP-000427

    <GroupDescription></GroupDescription>
    Group
  • The ISEC7 EMM Suite must allow the use of DoD PKI established certificate authorities for verification of the establishment of protected sessions.

    &lt;VulnDiscussion&gt;Untrusted Certificate Authorities (CA) can issue certificates, but they may be issued by organizations or individuals that se...
    Rule Medium Severity
  • SRG-APP-000439

    <GroupDescription></GroupDescription>
    Group
  • The ISEC7 EMM Suite must protect the confidentiality and integrity of transmitted information during preparation for transmission and during reception using cryptographic mechanisms.

    &lt;VulnDiscussion&gt;Without protection of the transmitted information, confidentiality and integrity may be compromised since unprotected communi...
    Rule Medium Severity

The content of the drawer really is up to you. It could have form fields, definition lists, text lists, labels, charts, progress bars, etc. Spacing recommendation is 24px margins. You can put tabs in here, and can also make the drawer scrollable.

Capacity
Modules